español  français
 Cable Details  
Generate pdf
EXZHELLENT SOLAR
ZZ-F (PVF-1 TÜV)


No flame propagationLow opacity fume emissionHalogen FreeLow acidity and corrosivity of emitted gasesFlexible ConductorHeavy dutyWeather resistanceMineral oil resistanceService at very low temeperatures (-40ºC)
CONDUCTOR
Tinned copper, flexible class 5
INSULATION
Halogen-free thermoset compound
SHEATH
Halogen-free thermoset compound

VOLTAGE
0,6/1 kV c.a. - 1,8 kV c.c.

STANDARDS
Specification TÜV Pfg 1169
IEC 60332-1 - Flame propagation (single wire)
IEC 60754 – Low corrosivity and acidity of evolved gases
IEC 61034 – Low opacity of evolved fumes


APPLICATIONS AND MAIN CHARACTERISTICS
For the connection between PV modules and between PV modules and inverters (i.e. DC Application).
Low fire hazard cable: flame retardant, halogen free and low opacity of evolved fumes.
Weather resistant.
Work at extreme ambient temperatures, from -40 ºC to +90 ºC.
Maximum conductor temperature of 120 ºC during 20.000 hours.
Excellent mechanical performance.
Mobile service.
Minimum service life of 25 years.
Current ratings at 60 ºC ambient temperature and 120 ºC conductor temperature.

Product certified by TÜV - Cert. No. R.60034574.

 Nominal SectionOverall DiameterWeightBending RadiusFree-air CurrentVoltage Drop 1
 mm2mmkg/kmmmAV/A.km
16141071x2,54.845204122.87
16141081x45.465225514.18
16141091x66.18525709.445
16141101x107.814031965.433
16141111x168.6195351323.455
16141121x2510.3290411762.215
16141131x3511.6390472181.574