español  français
 Cable Details  
Generate pdf
EXZHELLENT MAR
RDt


No flame propagationNo fire propagationLow opacity fume emissionHalogen FreeLow acidity and corrosivity of emitted gases
CONDUCTOR
Copper, semi-rigid class 2
INSULATION
Cross-linked polyethylene (XLPE)
SHEATH
Z1. Thermoplastic polyolefin

VOLTAGE
0.6/1 kV

STANDARDS
IEC 60092-350 – Design standard
IEC 60092-353 - Design standard
IEC 60092-351 - Design standard (insulation)
IEC 60092-359 - Design standard (sheath)
IEC 60332-1 - Flame propagation (single wire)
IEC 60332-3-22 - Flame propagation (bunched wires), cat. A
IEC 60754 – Halogen free. Low corrosivity and acidity of evolved gases
IEC 61034 – Low opacity of evolved fumes


APPLICATIONS AND MAIN CHARACTERISTICS
Cables for installation in ships with special non fire-propagation properties and low emission of opaque smoke and toxic and corrosives gases.

Maximum permanently-operating conductor temperature: 90 ºC

 Nominal SectionOverall DiameterWeightFree-air CurrentVoltage Drop 0.8
 mm2mmkg/kmAV/A.km
75912062X1.58.0702321.49
75912072X2.59.01203113.2
75912082X410.0150438.24
75913063X1.58.51052021.49
75913073X2.59.51452813.2
75913083X410.5175378.24
75913093X612.0275475.53
75913103X1014.0410653.32
75913113X1616.0605872.12
75913123X2519.59351101.37
75913133X3522.012651371.01
75913143X5028.019351670.76
75913153X7032.026752140.55
75913163X9536.035552590.42
75913173X12040.544753010.35
75913183X15045.054903470.29
75914064X1.59.51302021.49
75914074X2.510.51602813.2
75914084X411.5250378.24
75914094X613.0355475.53
75914104X1015.5525653.32
75914114X1617.5775872.12
75914124X2521.512001101.37
75914134X3524.516251371.01
75914144X5031.024401670.76
26160565X1.510.51652021.47
26160767X1.511.0200--21.47
26160575X2.511.52302813.17
26160777X2.512.5280--13.17
261612612X1.515.0330--21.47
261612712X2.516.5460--13.17
261619619X1.517.5480--21.47
261619719X2.519.5680--13.17
261627627X1.521.0665--21.47
261627727X2.524.0955--13.17

< Back

Legal Info  +34 93 227 97 00info@generalcable.es español  français